Description
Altronix ACM4E converts one (1) 12 to 24 VAC or VDC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form “C” contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4E will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes.
Features:
- Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
- Fire Alarm disconnect input options
- Normally open (NO) or normally closed (NC) dry contact input
- Polarity reversal input from FACP signaling circuit
- contact rated @ 1A 28VDC not evaluated by UL
- Removable terminal blocks facilitate ease of installation
Technical Specifications
Voltage
12 to 24 VAC or VDC
Current
- 0.4A @ 12V
- 0.2A @ 24V
Indicator
- Red LEDs: Outputs are triggered (relays energized)
- Green LED: FACP disconnect is triggered
Operating Temperature
0ºC to 49ºC (32ºF to 120ºF)
Operating Humidity
85% +/– 5%
Compliance
- UL294: Access Control
- cUL:General Signaling Equipment Evaluated
- to CSA Standard C22.2 No.205-M1983
Warranty
Lifetime Warranty
Warranty
Lifetime Warranty