Description
A simple, all-in-one kit for UniFi Access, designed to manage a single door with one reader. Supports seamless setup for modern, secure access control.
Technical Specifcations
Ambient operating humidity
5 to 90% noncondensing
Ambient operating temperature
-30 to 45° C (-22 to 113° F)
Button
(1) Factory-reset
CAN/ULC-60839-11-1 Grade
Grade assignment: I
Certifications
- CE
- FCC
- IC
- UL 294
- CAN/ULC-60839-11-1
Connectivity
BLE 4.1
Digital input
Request to exit/request to enter/remote release/door position sensor
Dimensions
3.37 x 2.13 x 0.03" (85.6 x 53.98 x 0.84 mm)
Document number, and issue date and/or revision level
- UA-G2/UA-G2-Black
- V02
Dry output relay
- Lock: 30V DC
- 1A Aux: 30V DC
- 1A
ESD/EMP protection
- Air: ±15kV
- contact: ±8kV
Enclosure material
- Polycarbonate
- glass
Format
ISO 7810 ID-1
LEDs
R/G/B/W (Learn more)
Max. power consumption
5W
Mounting
- In wall
- gang box
Mounting material
Polycarbonate
NFC frequency
13.56 MHz
NFC read range
< 30 mm
NFC technology
ISO/IEC 14443 Type A
MIFARE DESFire
UniFi Access Proprietary Security Protocol
Networking interface
(1) 10/100 MbE RJ45 port
Operating environment
Outdoor use
PoE input
- 50V DC
- 1A
PoE output
- PoE passthrough
- (4) PoE
- 50V DC
- total 20W
Power method
Powered output relay
- Lock: 12V DC
- 1A Aux: 12V DC
- 0.33A 12V DC
- 0.33A
Sensors
Proximity sensor
Software information
The software version of a product can be checked at https://unifi.ui.com
Speaker
- (1) 8 ohm
- 0.7W
Supported voltage range
48V DC
UL 294 level
UL 294 statement
- Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code
- ANSI/NFPA 70
- Article 725.121
- Power Sources for Class 2 and Class 3 Circuits.
Weatherproofing
IP55
Weight
0.18 oz (5 g)
Wiring gauge requirements (AWG)
Dimensions
85.6 x 53.98 x 0.84 mm (3.37 x 2.13 x 0.03")
Dry output relay
- Lock: 30V DC
- 1A
- Aux: 30V DC
- 1A
NFC technology
ISO/IEC 14443 Type A
PoE cabling requirements
- The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords
- 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
Power method
PoE
Powered output relay
- Lock: 12V DC
- 1A
- Aux: 12V DC
- 0.33A
- 12V DC
- 0.33A
UL 294 level
Destructive attack: Level I
UL 294 statement
- The equipment is intended to comply with the section of the National Electrical Code
- ANSI/NFPA 70
- Article 725.121
- Power Sources for Class 2 and Class 3 Circuits.
Weight
5 g (0.18 oz)
Wiring gauge requirements (AWG)
Technical Specifcations
Ambient operating humidity
5 to 90% noncondensing
Ambient operating temperature
-30 to 45° C (-22 to 113° F)
Button
(1) Factory-reset
CAN/ULC-60839-11-1 Grade
Grade assignment: I
Certifications
- CE
- FCC
- IC
- UL 294
- CAN/ULC-60839-11-1
Connectivity
BLE 4.1
Digital input
Request to exit/request to enter/remote release/door position sensor
Dimensions
3.37 x 2.13 x 0.03" (85.6 x 53.98 x 0.84 mm)
Document number, and issue date and/or revision level
- UA-G2/UA-G2-Black
- V02
Dry output relay
- Lock: 30V DC
- 1A Aux: 30V DC
- 1A
ESD/EMP protection
- Air: ±15kV
- contact: ±8kV
Enclosure material
- Polycarbonate
- glass
Format
ISO 7810 ID-1
LEDs
R/G/B/W (Learn more)
Max. power consumption
5W
Mounting
- In wall
- gang box
Mounting material
Polycarbonate
NFC frequency
13.56 MHz
NFC read range
< 30 mm
NFC technology
ISO/IEC 14443 Type A
MIFARE DESFire
UniFi Access Proprietary Security Protocol
Networking interface
(1) 10/100 MbE RJ45 port
Operating environment
Outdoor use
PoE input
- 50V DC
- 1A
PoE output
- PoE passthrough
- (4) PoE
- 50V DC
- total 20W
Power method
Powered output relay
- Lock: 12V DC
- 1A Aux: 12V DC
- 0.33A 12V DC
- 0.33A
Sensors
Proximity sensor
Software information
The software version of a product can be checked at https://unifi.ui.com
Speaker
- (1) 8 ohm
- 0.7W
Supported voltage range
48V DC
UL 294 level
UL 294 statement
- Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code
- ANSI/NFPA 70
- Article 725.121
- Power Sources for Class 2 and Class 3 Circuits.
Weatherproofing
IP55
Weight
0.18 oz (5 g)
Wiring gauge requirements (AWG)
Dimensions
85.6 x 53.98 x 0.84 mm (3.37 x 2.13 x 0.03")
Dry output relay
- Lock: 30V DC
- 1A
- Aux: 30V DC
- 1A
NFC technology
ISO/IEC 14443 Type A
PoE cabling requirements
- The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords
- 24 AWG (0.21 mm 2 ) for horizontal or riser cable.
Power method
PoE
Powered output relay
- Lock: 12V DC
- 1A
- Aux: 12V DC
- 0.33A
- 12V DC
- 0.33A
UL 294 level
Destructive attack: Level I
UL 294 statement
- The equipment is intended to comply with the section of the National Electrical Code
- ANSI/NFPA 70
- Article 725.121
- Power Sources for Class 2 and Class 3 Circuits.
Weight
5 g (0.18 oz)
Wiring gauge requirements (AWG)